telefono

EILON - Ron-4000

E-mail

Descripción

Ron 4000 Load Cell with built-in Amplifier
Ron 4000C 4-20mA Output | Ron 4000V 0-2V Output | Ron 4000VC 0-2V + 4-20mA Outputs

TECHNICAL SPECIFICATIONS
 
  • Safety Factor: 5:1.
  • Proof Load: Each system proof-loaded to 200% of capacity (certified) up to a test force of 400t.
  • Load Cell Material: High-strength, aerospace quality alloy steel, polyurethane coated.
  • Linearity: 0.1% f.s
  • Input: 9 to 48 vdc
  • Output: 0 to 2v. Options: 4 to 20mA, 0 to 2v + 4 to 20mA.
  • Cable: supplied with 9' (3m) cable.
  • Temperature Range: -15°f to +175°f (-25°c to +80°c).
  • Environmental: Weatherproof, NEMA 4, IP 65.
  • Calibration:    Supplied    with    approximate    calibration     (final
  • calibration is performed by the customer, after connecting the load cell to the measuring / control 
  • system).
  • Zero load = 0+0.05v, 4±0.2mA. Full load = 2-0.1v, 20-1mA.
  • Max. Input Current: 100mA.
  • Wiring:
  • Input voltage Red Common Black Output V White Output A Green
  • Body without insulation
 

 

Soporte